{"id":1423,"date":"2019-04-23T14:54:44","date_gmt":"2019-04-23T18:54:44","guid":{"rendered":"https:\/\/www.precisionot.com\/?p=1423"},"modified":"2023-06-12T15:39:02","modified_gmt":"2023-06-12T19:39:02","slug":"faserpolaritat-alles-was-sie-wissen-mussen","status":"publish","type":"post","link":"https:\/\/www.precisionot.com\/de\/fiber-polarity-everything-you-need-know\/","title":{"rendered":"Faserpolarit\u00e4t: Alles, was Sie wissen m\u00fcssen"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"1423\" class=\"elementor elementor-1423\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-47f10d15 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"47f10d15\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4e87ba32\" data-id=\"4e87ba32\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-60abb2e6 elementor-widget elementor-widget-text-editor\" data-id=\"60abb2e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n<p><span data-contrast=\"auto\">Erfolgreiche Installation eines Glasfasernetzes mit <\/span><a href=\"https:\/\/www.corning.com\/data-center\/worldwide\/en\/home\/knowledge-center\/maximizing-the-advantages-of-the-mtp-connector.html#:~:text=multifiber%20push%2Don%20(MPO)%20connector\" target=\"_blank\" rel=\"noopener\"><span data-contrast=\"none\">Mehrfaser-Push-on (MPO)<\/span><\/a><span data-contrast=\"auto\"> Die Qualit\u00e4t von Kabeln und Steckverbindern h\u00e4ngt von mehreren \u00dcberlegungen ab, eine der wichtigsten davon ist die Faserpolarit\u00e4t.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Im Grunde definiert die Polarit\u00e4t die Richtung des Stromflusses zwischen zwei Punkten oder Polen. Negative Pole haben im Vergleich zu positiven Polen eine gr\u00f6\u00dfere Anzahl an Elektronen; Wenn es angeschlossen ist, flie\u00dft elektrischer Strom von negativ nach positiv. Im Zusammenhang mit der Glasfaserkommunikation ist dies analog zum Datenfluss in Form von Lichtsignalen vom Sender (Tx) zum Empf\u00e4nger (Rx). Eine Glasfaserverbindung kann nur funktionieren, wenn Tx an einem Ende mit Rx am anderen Ende verbunden ist und umgekehrt; Dies wird erreicht, indem eine Faserpolarit\u00e4tsumkehr erzeugt wird, die an einem bestimmten Punkt der Verbindung Tx gegen Rx vertauscht.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n\n<h2 class=\"wp-block-heading\" id=\"h-duplex-configurations\"><span class=\"TextRun MacChromeBold SCXW145714309 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun CommentStart SCXW145714309 BCX0\">Duplex-Konfigurationen<\/span><span class=\"NormalTextRun SCXW145714309 BCX0\"> und Faserpolarit\u00e4t<\/span><\/span><span class=\"EOP SCXW145714309 BCX0\" data-ccp-props=\"{&quot;201341983&quot;:2,&quot;335559740&quot;:630}\">\u00a0<\/span><\/h2>\n\n<p><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">Bei Duplex\u00fcbertragung ist dies der Fall <\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">relativ einfach<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\"> Zu <\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">erreichen<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">. Ein AB-Duplex-Patchkabel <\/span><\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">hat eine k\u00f6rperliche <\/span><\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">direkte Verbindung zweier Fasern zwischen Empfang <\/span><\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">(<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">B)<\/span> <\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">und \u00fcbermitteln<\/span> <\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">(A)<\/span> <\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">Verbinder<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">S<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">.<\/span><\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">\u00a0<\/span> <span class=\"NormalTextRun SCXW199469246 BCX0\">B<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">Aus diesem Grund B nach A a<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">Da es sich um eine A-zu-B-Verbindung handelt, wird sie als Cross-Over bezeichnet <\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">Die A-Position geht in die B-Position \u00fcber und umgekehrt<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">A<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">.<\/span><\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW199469246 BCX0\">\u00a0<\/span> <\/span><span class=\"TextRun SCXW199469246 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW199469246 BCX0\">A<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">Ein Ausrichtungsschl\u00fcssel verhindert, dass sich die Faser dreht, wenn die Steckverbinder mit dem Kabel verbunden sind. Von einem Ende zum anderen betrachtet gibt es eine einzelne Faser, die A mit B verbindet, und eine weitere einzelne Faser, die B mit A verbindet; Daten flie\u00dfen bidirektional und <\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">Faser <\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">Polarit\u00e4t ist<\/span> <span class=\"NormalTextRun SCXW199469246 BCX0\">M<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">aintaine<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">D<\/span><span class=\"NormalTextRun SCXW199469246 BCX0\">.<\/span><\/span><span class=\"EOP SCXW199469246 BCX0\" data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3395\" src=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/a-b-duplex-patch-cord.png\" alt=\"Ab-Duplex-Patchkabel\" width=\"442\" height=\"233\" srcset=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/a-b-duplex-patch-cord.png 831w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-b-duplex-patch-cord-600x317.png 600w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-b-duplex-patch-cord-300x158.png 300w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-b-duplex-patch-cord-768x406.png 768w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-b-duplex-patch-cord-16x8.png 16w\" sizes=\"(max-width: 442px) 100vw, 442px\" \/><\/figure>\n<\/div>\n\n<p><span class=\"TextRun SCXW90602044 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW90602044 BCX0\">Es gibt auch AA-Duplex-Patchkabel<\/span><\/span><span class=\"TextRun SCXW90602044 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"> <span class=\"NormalTextRun SCXW90602044 BCX0\">physisch<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\"> gekreuzt<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">, <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">noch<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\"> Position A bleibt an Position A und Position B bleibt an Position <\/span><span class=\"NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW90602044 BCX0\">B<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\"> daher wird es als Str bezeichnet<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">aight-through-Verbindung.<\/span> <\/span><span class=\"TextRun SCXW90602044 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW90602044 BCX0\">Diese Art von Kabel ist <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">allgemein verwendet<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\"> gegen\u00fcber einer AB-Schnur wo <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">Die <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">Faser <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">Es ist bereits ein Polarit\u00e4ts\u00fcbergang stattgefunden und <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">muss sein <\/span><span class=\"NormalTextRun SCXW90602044 BCX0\">gepflegt<\/span><span class=\"NormalTextRun SCXW90602044 BCX0\"> (anstatt durch erneutes \u00dcberqueren r\u00fcckg\u00e4ngig gemacht zu werden).<\/span><\/span><span class=\"EOP SCXW90602044 BCX0\" data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" class=\"wp-image-3396\" src=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/a-a-duplex-patch-cord.png\" alt=\"AA-Duplex-Patchkabel\" width=\"432\" height=\"228\" srcset=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/a-a-duplex-patch-cord.png 827w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-a-duplex-patch-cord-300x159.png 300w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-a-duplex-patch-cord-768x406.png 768w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-a-duplex-patch-cord-16x8.png 16w, https:\/\/www.precisionot.com\/wp-content\/uploads\/a-a-duplex-patch-cord-600x317.png 600w\" sizes=\"(max-width: 432px) 100vw, 432px\" \/><\/figure>\n<\/div>\n\n<h2 class=\"wp-block-heading\" id=\"h-multi-fiber-configurations\"><br \/><span class=\"NormalTextRun CommentStart SCXW128181434 BCX0\">Konfigurationen mit mehreren Fasern<\/span><span class=\"NormalTextRun SCXW128181434 BCX0\"> und Faserpolarit\u00e4t<\/span><span class=\"NormalTextRun SCXW128181434 BCX0\">\u00a0<\/span><\/h2>\n\n<p><span data-contrast=\"auto\">Die Industrie hat drei verschiedene Methoden zur Aufrechterhaltung der Faserpolarit\u00e4t in Mehrfaseranwendungen identifiziert. Bei jedem handelt es sich um unterschiedliche Arten von MPO-Kabeln und -Steckern.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Methode A verwendet durchgehende MPO-Array-Kabel, um die Fasern an jedem Ende der Verbindung auf die gleiche Weise abzubilden. Sie werden \u00fcber Adapter oder Kassetten vom Typ A verbunden, die eine \u201eKey-Up\/Key-Down\u201c-Ausrichtung haben. Dies bezieht sich auf die Platzierung der Kerben, die die Ausrichtung beim Zusammenstecken des Steckverbinders an beiden Enden gew\u00e4hrleisten. <\/span><span data-contrast=\"auto\">Bei Betrachtung der Faserendfl\u00e4che werden die Faserpositionen von links nach rechts beginnend mit P1 nummeriert. Die P1-Position ist \u00fcblicherweise auch mit einem wei\u00dfen Punkt an der Seite des Steckergeh\u00e4uses gekennzeichnet.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Die Konfiguration nach Methode A \u00fcbertr\u00e4gt sich auf die Faser in P1 (Tx) auf der linken Seite und erreicht P1 (Tx) auf der rechten Seite am anderen Ende. Da Methode A nicht die erforderliche Tx-zu-Rx-Faserpolarit\u00e4tsumkehr beinhaltet, wird sie mit A durchgef\u00fchrt<\/span><span data-contrast=\"auto\">\u2013<\/span><span data-contrast=\"auto\">B<\/span><span data-contrast=\"auto\"> An einem Ende ist ein Duplex-Patchkabel und am anderen Ende ein AA-Duplexkabel angebracht, um die Umkehrung aufrechtzuerhalten. <\/span><span data-contrast=\"auto\">Diese Methode gilt als einfache Bereitstellungsmethode sowohl f\u00fcr Singlemode- als auch f\u00fcr Multimode-Kan\u00e4le und kann Netzwerkerweiterungen f\u00fcr eine einfache Skalierbarkeit unterst\u00fctzen.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-19793 size-full\" style=\"text-align: center; font-style: inherit; font-weight: inherit;\" src=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics.webp\" alt=\"Typ A-Faserpolarit\u00e4t \" width=\"675\" height=\"284\" srcset=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics.webp 675w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics-300x126.webp 300w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics-18x8.webp 18w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics-600x252.webp 600w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics-64x27.webp 64w\" sizes=\"(max-width: 675px) 100vw, 675px\" \/><\/p>\n\n<p><img \/><\/p>\n<p><span data-contrast=\"auto\">Methode B verwendet gekreuzte MPO-Array-Kabel mit Typ-B-Key-Up-Anschl\u00fcssen an beiden Enden, wodurch die Faserpolarit\u00e4tsumkehr erfolgt, ohne dass ein AA-Patchkabel an einem Ende erforderlich ist; Beide Enden k\u00f6nnen befestigt werden <\/span><span data-contrast=\"auto\">gerade<\/span><span data-contrast=\"auto\"> AB-Duplex-Patchkabel<\/span><span data-contrast=\"auto\">, wodurch die ben\u00f6tigten Duplex-Jumper vereinfacht werden.<\/span><span data-contrast=\"auto\"> Bei einem herk\u00f6mmlichen 12-Faser-Stecker bedeutet Methode B, dass die Faser in P1 (Tx) am anderen Ende bei P12 (Rx) ankommt, die Faser in P2 (Rx) bei P11 (Tx) ankommt und so weiter.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Ein Nachteil dieser Methode besteht darin, dass die P12-Faser letztendlich am Ende der Verbindung wieder mit P1 verbunden werden muss. In einem kassettenbasierten System erfordert dies das physische Umdrehen einer Kassette und erh\u00f6ht die Komplexit\u00e4t der Netzwerkverwaltung. Methode B unterst\u00fctzt auch keine Singlemode-Verbindungen mit APC-Polierh\u00fclsen (Angled Physical Contact), da die Winkel der Gegenstecker nicht komplement\u00e4r sind. Eine wichtige Verwendung eines Array-Patchkabels vom Typ B besteht jedoch darin, dass es zum Umdrehen der Faserpolarit\u00e4t bei der Polarit\u00e4tsverwaltung paralleler Signale nach Methode A verwendet werden kann. Dort ersetzt es das oben beschriebene AA-Duplex-Patchkabel, das f\u00fcr ein Duplex-Signal geeignet ist.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-19794 size-full aligncenter\" src=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics2.webp\" alt=\"Typ B-Faserpolarit\u00e4t\" width=\"675\" height=\"284\" srcset=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics2.webp 675w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics2-300x126.webp 300w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics2-18x8.webp 18w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics2-600x252.webp 600w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics2-64x27.webp 64w\" sizes=\"(max-width: 675px) 100vw, 675px\" \/><\/figure>\n<\/div>\n\n<p><span data-contrast=\"auto\">Methode C weist \u00c4hnlichkeiten mit beiden oben genannten Methoden auf. Wie bei Methode A werden Key-Up\/Key-Down-Anschl\u00fcsse vom Typ A verwendet, und wie bei Methode B k\u00f6nnen beide Enden an geraden AB-Duplex-Patchkabeln befestigt werden. Der Unterschied liegt in der Umkehrung der Faserpolarit\u00e4t, die durch gekreuzte Paare innerhalb des MPO-Array-Kabels selbst erzeugt wird: P1 (Tx) kommt bei P2 (Rx) am gegen\u00fcberliegenden Ende an und umgekehrt, P3 und P4 sind auf \u00e4hnliche Weise gekreuzt und so weiter.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Diese Methode erfordert eine detailliertere Planung f\u00fcr das Faserpolarit\u00e4tsmanagement und kann auch bei parallelen Signalen im Gegensatz zu Duplex problematisch sein. Beispielsweise wird eine 40G- oder 100G-Anwendung mit acht Fasern nicht von einem gekreuzten Array-Kabel mit 12 Fasern unterst\u00fctzt, das P1-P4 als sendend und P9 bis P12 als empfangend festlegen w\u00fcrde. Da die Skalierbarkeit von Netzwerken bei hohen Geschwindigkeiten immer wichtiger wird, nimmt auch diese Einschr\u00e4nkung zu.<\/span><span data-ccp-props=\"{&quot;335559739&quot;:420}\">\u00a0<\/span><\/p>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-19795 size-full aligncenter\" src=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics3.webp\" alt=\"Typ-C-Faserpolarit\u00e4t\" width=\"675\" height=\"284\" srcset=\"https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics3.webp 675w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics3-300x126.webp 300w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics3-18x8.webp 18w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics3-600x252.webp 600w, https:\/\/www.precisionot.com\/wp-content\/uploads\/FiberPolarityBlogGraphics3-64x27.webp 64w\" sizes=\"(max-width: 675px) 100vw, 675px\" \/><\/figure>\n<\/div>\n\n<p><img \/><strong>Fazit<\/strong><\/p>\n\n<p><a class=\"Hyperlink SCXW141129459 BCX0\" href=\"https:\/\/www.fiercetelecom.com\/broadband\/14m-us-businesses-now-connected-fiber-vertical-systems-group#:~:text=Enterprise%20fiber%20connectivity%20in%20the%20U.S.%20ramped%20up%20in%202022%2C%20reaching%20more%20than%201.4%20million%20commercial%20buildings%20and%20data%20centers%20in%202022\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"TextRun Underlined SCXW141129459 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW141129459 BCX0\" data-ccp-charstyle=\"Hyperlink\">Die Glasfaserkonnektivit\u00e4t nimmt weiter zu<\/span><\/span><\/a><span class=\"TextRun SCXW141129459 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW141129459 BCX0\">, machen f<\/span><span class=\"NormalTextRun SCXW141129459 BCX0\">iber p<\/span><span class=\"NormalTextRun SCXW141129459 BCX0\">Solarit\u00e4tsmanagement<\/span><span class=\"NormalTextRun SCXW141129459 BCX0\"> wichtiger denn je<\/span><span class=\"NormalTextRun SCXW141129459 BCX0\">.\u00a0 <\/span><span class=\"NormalTextRun SCXW141129459 BCX0\">W\u00e4hrend Faserpolarit\u00e4t<\/span> <span class=\"NormalTextRun SCXW141129459 BCX0\">Da das Multifaser-Zeitalter ein komplexes Thema ist, dienen die Grundprinzipien, die f\u00fcr einfache Anwendungen gelten, weiterhin als Bausteine f\u00fcr die Schaffung dauerhafter Netzwerkl\u00f6sungen. Kontaktieren Sie die Experten unter<\/span><\/span><a class=\"Hyperlink SCXW141129459 BCX0\" href=\"https:\/\/www.precisionot.com\/de\/\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"TextRun Underlined SCXW141129459 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW141129459 BCX0\">Pr\u00e4zisionsoptische Technologien<\/span><\/span><\/a><span class=\"TextRun SCXW141129459 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW141129459 BCX0\">um mehr zu lernen.<\/span><\/span><span class=\"EOP SCXW141129459 BCX0\" data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Die erfolgreiche Installation eines Glasfasernetzwerks mit Mehrfaser-Push-On-Kabeln (MPO) und Steckverbindern h\u00e4ngt von mehreren \u00dcberlegungen ab, von denen eine der wichtigsten die Polarit\u00e4t ist.<\/p>","protected":false},"author":33,"featured_media":19803,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[6,246],"tags":[],"class_list":["post-1423","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-operational-technologies"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/posts\/1423","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/comments?post=1423"}],"version-history":[{"count":0,"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/posts\/1423\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/media\/19803"}],"wp:attachment":[{"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/media?parent=1423"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/categories?post=1423"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.precisionot.com\/de\/wp-json\/wp\/v2\/tags?post=1423"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}